Gorman-Rupp PA4A60 Prime Aire Pump

Spare Parts for the Gorman-Rupp PA4A60 Priming-assisted dewatering pump

This page lists genuine OEM spare parts for Gorman-Rupp pumps.
Pump Spares Direct is an independent supplier and is not affiliated with, endorsed by, or authorised by Gorman-Rupp.

Image shown for pump identification purposes only.

DOWNLOAD DATASHEET

Product Summary

Genuine OEM spare parts for the Gorman-Rupp PA4A60, a priming-assisted pump that primes and re-primes automatically using a vacuum-assisted priming system, usually supplied as an engine-driven set. Impellers, seals, wear parts, check valves and bearings, plus priming-system parts, are listed below with Gorman-Rupp part numbers from manual OM-07575-01.

Type: priming-assisted dewatering pump Series: Prime Aire (PA Series) Ports: 4" (100 mm) Solids: up to 3.00" (76 mm) Manual: OM-07575-01 (S/N 1854919 and up) Pump end & priming system only

Spare Parts List

✓ Tick the parts you need. Codes are as printed in the Gorman-Rupp parts list; build variants and older serial numbers can use different parts, so pick your model in the form below. Not sure? Add a photo of the nameplate (model and serial number) and we’ll match the parts for you.

SelectPart (as printed by Gorman-Rupp)Part number & reference
Wear & Service Parts
ImpellerPart no. 10528 11010 · Item 1
Cartridge Seal AssyPart no. 46513-151 · Item 3
Wear Plate AssyPart no. 10532B 15990 · Item 2
Check Valve KitPart no. 48274-003 · Item 7
Check ValvePart no. 26642-145
FlapperPart no. 26688-005
Repair Rotating AssyPart no. 44163-594 · Item 3
Shim SetPart no. 13130 17040 · Item 8 · Qty 4
Impeller Adjusting Shim SetPart no. 37J 17090 · Item 2 · Qty REF
Seals, Bearings & Shaft
Cover Plate GasketPart no. 38689-037 18000 · Item 9
Flange GasketPart no. 1676G 18000 · Item 2
Flange GasketPart no. 25113-034
Cover O-RingPart no. 25152-366
O-RingPart no. 25154-273 · Item 6
O-RingPart no. S1674 · Item 7
Seal PlatePart no. 38272-234 10010 · Item 4
GasketPart no. 10959G 20000 · Item 5
Oil SealPart no. S1352 · Item 6
GasketPart no. 38683-275 18000 · Item 19
Ball BearingPart no. S375 · Item 22
Impeller ShaftPart no. 38514-822 1706H · Item 24
Ball BearingPart no. S1088 · Item 25
O-RingPart no. 25154-022 · Item 26 · Qty REF
O-RingPart no. 25152-273 · Item 28
Priming Valve GasketPart no. 38683-657 19060 · Item 4
Priming System
Priming Chamber KitPart no. 48275-005 · Item 12
Priming ValvePart no. 26664-007 · Item 1
Orifice ButtonPart no. 26688-021
Priming ChamberPart no. 38343-020 10000 · Item 5
Strainer AssyPart no. 46641-222 17000 · Item 6
Other Core Parts
Sight GaugePart no. S1471 · Item 14
Repair Pump Casing AssyPart no. 46474-354
Mounting FlangePart no. 38545-005 10000 · Item 18

How we confirm the exact part: Part numbers on this page are as printed in Gorman-Rupp manual OM-07575-01, parts list for serial numbers 1854919 and up. Pumps with earlier serial numbers, an “N” serial suffix or a different build can use different parts, so send the serial number or a nameplate photo and we’ll confirm the right part before we quote. Engine and power-unit parts are not covered on this page.

Service Intervals & When to Replace

  • Daily: check general condition (temperature, noise, vibration, leaks) and pump performance (gauges, speed, flow).
  • Lubrication: check bearing and seal-cavity lubrication weekly; replace the oil annually (Gorman-Rupp specifies SAE No. 30 non-detergent oil where oil is used).
  • Every six months: inspect front impeller clearance (wear plate) and rear clearance (seal plate) and adjust or replace worn parts.
  • Annually: inspect the check valve, bearings, shaft deflection and pump-to-driver alignment; clean the pressure relief valve.
  • New applications: inspect wearing parts after the first 250 hours to set your wear rate. Intervals assume about 4,000 hours a year of intermittent duty; shorten them for abrasive or continuous duty.

Models

One page covers the PA4A60 pump end across its engine and drive builds. The pump end, priming chamber and check valve parts are common; engine parts are not listed. The full model code is on the pump nameplate.

PA4A60-4045T S5PA4A60D-4045T S5PA4A60-4045T FT4-ESPPA4A60C-4LE2T FT4PA4A60C-C2.2T FT4PA4A60C-F3L

Models & Key Specifications

ModelSeriesPorts (suction x discharge)Max solidsSeal (as listed)Parts list
PA4A60Prime Aire (PA Series)4" (100 mm)3.00" (76 mm)Cartridge Seal AssyOM-07575-01 (S/N 1854919+)

Port size and solids handling from Gorman-Rupp model data; parts from manual OM-07575-01. Typical uses: site and mine dewatering, bypass pumping and hire fleets.

Troubleshooting

Pump fails to prime

Likely cause: Discharge check valve contaminated, damaged or not seating, an air leak in the suction line, a worn seal or gasket, a damaged air compressor or broken belt, or a clogged strainer. Action: Clean or replace the check valve, correct leaks, check pump vacuum and replace the worn seal or gasket, repair the compressor or belts, and clean the strainer.

Low flow or pressure

Likely cause: Eductor or strainer clogged, impeller or other wearing parts worn or damaged, or suction lift too high. Action: Clean the eductor and strainer, replace worn parts and check the impeller is centred and turns freely, and reduce suction lift.

Pump clogs frequently

Likely cause: Discharge flow too slow, a clogged or binding check valve, or liquid too thick. Action: Open the discharge valve fully, run at full governed speed, clean the check valve and dilute if possible.

Pump requires too much power

Likely cause: Pump speed too high, discharge head too low, liquid too thick, or a frozen pump or jack shaft bearing. Action: Check driver output, adjust the discharge valve, dilute if possible, and check and replace bearings.

Request for Quotation

Selected Parts:

  • No parts selected

Not sure which parts? Just send a photo of the nameplate or part below.

Your pump

Please select your PA4A60 build (or choose “Not sure”)

Your details

Please enter your full name
Please enter a valid email address
Please enter a valid phone number

Your enquiry

Please select what you need

Drag & drop image here or tap to browse

JPG, PNG or PDF, max 5MB

File must be smaller than 5MB

Delivery

Please select when you need it
Please enter the delivery suburb or town
Please enter a 4-digit postcode
Postcode and state don't match - please check
Please select a state
Please select a delivery type

We use these details only to prepare and follow up your quote. See our Privacy Policy.

We aim to respond within one business day

Gorman-Rupp PA4A60 spare parts: frequently asked questions

Tap a question to see the answer.

What spare parts are listed for the Gorman-Rupp PA4A60?

Parts come from Gorman-Rupp manual OM-07575-01, grouped as wear and service parts; seals, bearings and shaft; priming system; and other core parts. They include the impeller, cartridge seal assembly, wear plate assembly, check valve kit, check valve and flapper, each listed with its Gorman-Rupp part number as printed.

Why won’t my PA4A60 prime?

Likely causes from the troubleshooting guide: discharge check valve contaminated, damaged or not seating, an air leak in the suction line, a worn seal or gasket, a damaged air compressor or broken belt, or a clogged strainer. The fixes are in the troubleshooting table above.

How do I restore lost flow or pressure on a PA4A60?

The troubleshooting guide on this page lists the likely causes as: eductor or strainer clogged, impeller or other wearing parts worn or damaged, or suction lift too high. Clean the eductor and strainer, replace worn parts and check the impeller is centred and turns freely, and reduce suction lift.

How do I make sure I order the right PA4A60 parts?

Tick the parts you need and your selection carries into the quote form. Add a nameplate photo or serial number and we’ll confirm the parts before quoting. See other models in our Prime Aire Series parts, or all Gorman-Rupp spare parts.