Gorman Rupp T3A3S-B Pump

Spare Parts for T3A3S-B Self Priming Pump

This page lists replacement and compatible spare parts for Gorman Rupp  pumps.
Pump Spares Direct is an independent supplier and is not affiliated with, endorsed by, or authorised by Gorman Rupp 

Image shown for pump identification purposes only.

Product Summary 

The Gorman-Rupp Super T Series T3A3S-B is a rugged self-priming centrifugal pump engineered for demanding applications involving liquids with large entrained solids and slurries. Featuring proven performance in municipal wastewater, mining, industrial processing, and construction dewatering, this pump delivers reliable operation with minimal maintenance requirements and exceptional solids-handling capability.

  • Superior Solids Handling: Handles up to 2.5-inch diameter spherical solids with 3-inch suction and 1.5-inch BSP discharge connections, ideal for sewage bypass, mine dewatering, and industrial slurry applications
  • True Self-Priming Design: Achieves 6-meter maximum suction lift with fast repriming capability, eliminating need for foot valves in most applications and enabling flexible installation configurations
  • Heavy-Duty Construction: Cast iron or optional stainless steel components with hardened wear surfaces, mechanical cartridge seal, and pressure relief valve protection for extended service life in abrasive environments
  • Field-Serviceable Design: Simple back cover removal provides full access to wear plate, impeller, and seal without disconnecting piping, minimizing downtime for routine maintenance and repairs
  • Multiple Drive Options: Available with electric motor (240V single-phase or 415V three-phase), engine drive, or bare shaft configuration with flexible coupling or V-belt drive arrangements

DOWNLOAD DATASHEET

Spare Parts List

Select the required parts below to include them in your quote request.

Select Qty Part Number Description Material / Spec
1 44163-259 Repair Rotating Assembly (Complete) Includes impeller, seal, bearings, shaft - Standard model
1 44163-304 Repair Rotating Assembly (/WW Variant) For wastewater applications
1 44163-270 Repair Rotating Assembly (/WWS Variant) Stainless steel for wastewater
1 11406 Impeller Open recessed non-clog design, cast iron
1 46513-150 Cartridge Seal Assembly (Standard) Complete mechanical seal with sleeve
1 11407A Wear Plate Assembly Replaceable impeller wear surface
1 11837D Seal Plate Seal mounting surface, cast iron
1 38514-563 Impeller Shaft Hardened alloy steel
1 46411-060 Flap Valve Assembly (Check Valve) Suction check valve, complete assembly
1 S1749 Ball Bearing (Inboard) Shielded ball bearing
1 23252-013 Ball Bearing (Outboard) Shielded ball bearing with snap ring
3 S1352 Oil Seal Lip seal (set of 3 required)
1 38251-410 Bearing Housing Cast iron housing
1 42111-801 Back Cover Plate Assembly Includes pressure relief valve
1 26662-005 Pressure Relief Valve Safety relief valve (replace at each overhaul)
1 38322-219 Bearing Cap Outboard bearing cover
1 10959G Gasket (Seal Plate) Seal plate gasket
1 38683-268 Bearing Cap Gasket Bearing cap sealing gasket
2 S1748 O-Ring (Housing/Back Cover) Nitrile rubber O-ring (set of 2)
1 25154-447 O-Ring (Viton - Chemical Resistant) For chemical applications
1 N0608 Shaft Key Drive shaft key
1 31167-029 Impeller Washer Hardened impeller thrust washer
1 S244 Snap Ring Bearing retaining snap ring
1 37J Impeller Adjustment Shim Set For setting impeller-to-seal plate clearance
1 48711-020 Disassembly Tool (Optional) For rotating assembly removal

OEM part numbers are referenced for identification purposes only.
All parts listed are suitable for use in T3A3S-B Pump.

Exploded Parts Views 

Exploded view shown for reference only. Part numbering may vary by configuration.

Key Technical Specifications 

Parameter Value
Model / Series T3A3S-B Super T Series (Including /F, /FM, /WW, /WWS variants)
Flow Performance See performance curve (Page E-1 of manual) - Varies by speed and head
Rated Power Varies by application (Typical motor: 1.25-2.5 kW)
Voltage / Frequency 240V Single-Phase / 415V Three-Phase, 50Hz (Other voltages available)
Suction / Discharge Connection 3" Suction / 1.5" BSP Discharge (Optional ASA or DIN flanges available)
Maximum Suction Lift 6 metres (20 feet)
Solids Handling Capability Up to 2.5" (63.5mm) diameter spherical solids
Maximum Liquid Temperature 160°F (71°C)
Impeller Type Open Recessed Non-Clog Centrifugal
Rotation Direction Counterclockwise (viewed from impeller end)
Seal Type Cartridge Mechanical Seal (Standard), Optional packing available
Materials of Construction Cast Iron (Standard), Stainless Steel options available (/WWS variant)
Installation Type Horizontal Baseplate Mounted, Self-Priming

Troubleshooting, Common Faults & Solutions

Pump Fails to Prime

Likely Cause: Strainer clogged, suction lift too high, leaking seal or gasket, collapsed suction hose lining, or air leak in suction line

Action / Part: Clean strainer, verify suction lift within 6m maximum, check pump vacuum (should pull 20" Hg or more), replace leaking seal (46513-150) or gaskets (10959G, S1748), replace collapsed suction hose, seal all suction line connections with pipe dope

Pump Stops or Fails to Deliver Rated Flow/Pressure

Likely Cause: Air leak in suction, worn seal/gasket, insufficient liquid in casing, contaminated check valve, plugged air release valve, clogged impeller, discharge head too low, or worn impeller/wear plate

Action / Part: Seal suction leaks, replace seal (46513-150) or gaskets, refill pump casing through fill cover (priming), clean/replace check valve assembly (46411-060), clear air release valve/piping, remove impeller debris, adjust discharge valve, check impeller-to-wear plate clearance (.010-.020"), replace worn impeller (11406) and/or wear plate assembly (11407A)

Pump Requires Too Much Power

Likely Cause: Pump speed too high, discharge head too low, liquid too thick

Action / Part: Check driver output speed, verify sheaves/couplings correctly sized, adjust discharge valve to increase head, dilute liquid if possible, open discharge valve fully and run at maximum governed speed

Pump Clogs Frequently

Likely Cause: Strainer clogged, check valve binding, suction lift too high, impeller clogged/damaged, pump speed too slow, or suction intake not properly submerged

Action / Part: Clean strainer regularly, clean check valve (46411-060), verify suction lift within 6m, clear impeller debris or replace if damaged (11406), check driver output for proper speed, verify belts/couplings not slipping, ensure suction intake submerged per manual Figure 2 specifications

Excessive Noise / Cavitation

Likely Cause: Cavitation (air in liquid, blocked foot valve/strainer, restriction in line, excessive suction lift), pump not securely mounted, or pumping entrained air

Action / Part: Reduce suction lift and friction losses, clean foot valve/strainer, record vacuum/pressure gauge readings (consult factory if needed), secure all mounting hardware, eliminate air bubble source, verify proper suction pipe submergence

Bearings Run Too Hot

Likely Cause: Low/incorrect lubricant, drive misaligned, pump speed too high, bearing frozen, or piping not properly supported

Action / Part: Note: Bearings normally run to 160°F (71°C). Check SAE No. 30 non-detergent oil level via sight gauge (14A) - maintain at middle of gauge, align drive properly (see manual Section B), reduce power source speed, check/replace bearings (S1749, 23252-013) if frozen, support suction/discharge lines independently

Seal Leakage

Likely Cause: Worn/damaged cartridge seal, insufficient seal cavity lubrication, or contaminated seal faces

Action / Part: Replace complete cartridge seal assembly (46513-150) - never reuse old seal, fill seal cavity with SAE No. 30 non-detergent oil to middle of sight gauge (14), verify seal plate gasket (10959G) not leaking, check O-rings (S1748) for damage

Pump Overheats / Pressure Relief Valve Activates

Likely Cause: Operating against closed discharge valve, insufficient flow, liquid temperature exceeds 160°F (71°C), or pump running dry

Action / Part: CRITICAL: Stop pump immediately if overheated - allow complete cooling before servicing. Never remove covers/plugs from hot pump. Open discharge valve, verify sufficient flow, cool liquid if over 160°F, refill pump casing if run dry (priming), replace pressure relief valve (26662-005) after any overheating event

Incorrect Rotation (Three-Phase Motors)

Likely Cause: Three-phase wiring incorrect

Action / Part: CRITICAL: Correct rotation is counterclockwise when facing impeller. Running pump in reverse will cause impeller to unscrew from shaft, causing severe damage. Disconnect pump from motor before checking rotation. Have qualified electrician interchange any two of three phase wires to change direction

Online Resources

Alt image
Request for Quotation

Request for Quotation

Thank you!

Your Request for Quote has been successfully sent.
Our team is reviewing your requirements and will be in touch shortly.

Selected Parts:

  • No parts selected
Please enter your full name
Please enter your company name
Please enter a valid email address
Please enter your phone number

Drag & drop image here or click to browse

Accepted formats: JPG, PNG, PDF (Max 5MB)

File size must be less than 5MB
Please select delivery urgency
Please select delivery location
Note on Minimum Orders: A standard minimum order value (MOV) of $1,000 AUD typically applies to process B2B commercial orders efficiently.

We typically respond within 24 hours