Grundfos SE1 Pumps

Spare Parts for SE1 Range Pumps

This page lists replacement and compatible spare parts for Grundfos pumps.
Pump Spares Direct is an independent supplier and is not affiliated with, endorsed by, or authorised by Grundfos.

Image shown for pump identification purposes only.

DOWNLOAD DATASHEET

Product Summary

Genuine and compatible spare parts for the Grundfos SE1 closed S-tube sewage pump, used across Australia in council sewage pump stations, stormwater and industrial wastewater duties, built for dry or submerged installation with a cooling jacket. Every SE1 from the 1.5 kW SE1.80.80 to the 26.5 kW SE1.80.100 shares the same service build (closed channel impeller, mechanical shaft seal and sealed, sensor-protected motor), so tick what you need and we’ll match the exact kit to your nameplate (e.g. SE1.100.100.30.4.50B).

Type: Submersible sewage pump, closed S-tube impeller Build: Cast iron · dry or wet with cooling jacket Range: 1.5–26.5 kW · DN65–DN200 · 50–110 mm solids

Spare Parts List

✓ Tick the parts you need. Grundfos SE1 service kits are matched to the hydraulic size, motor and build, so your nameplate model is all we need to get them right. Not sure which items? Add a photo of the nameplate and we’ll work out the kit for you.

SelectWear / Service ItemFunction & when to replace
Common Service Kits
Shaft Seal KitMechanical shaft seal kit (stationary and rotating parts, retaining ring, O-rings and spring washer) for your pump size; the 9–30 kW pumps use a double seal set. Replace at the first moisture alarm or if water shows in the oil.
Impeller KitThe closed S-tube impeller with its fixing parts, matched to your model and kW (e.g. SE1.80.80 at 5.5 kW). Replace if worn, cracked or eroded.
Wear & Seal Ring KitThe wear ring and seal ring on the suction side that set the impeller clearance. Replace when flow drops off or the pump starts ragging more than it used to.
O-ring & Gasket KitO-rings and gaskets for the pump housing, oil chamber and plugs. Renew whenever the pump is opened.
Cable KitReplacement power and sensor cable (15 m standard, 10 m on SE1.50.65; other lengths and screened cable for VSD use to order) with the cable entry seals. Fit if the cable is cut, crushed or wicking water.
Sensor KitMoisture switch, motor thermal switches or thermistors, and the water-in-oil (WIO) sensor on sensor-version (“A”) pumps. Replace a failed sensor so the pump stays protected.
Other Core Parts
Auto-Coupling & Guide Rail FittingsAuto-coupling base, guide claw and upper guide rail brackets, matched to your discharge size (DN65–DN200).
Cooling Jacket PartsCooling jacket and seals, plus horizontal or vertical dry-install brackets and base stands. Replace if damaged or leaking; a blocked jacket leads to overheating.
Lifting ChainLifting chain and shackles sized to the pump weight. Always lift by the chain, never the cable.
Oil Chamber OilFresh oil for the oil chamber at every seal change or inspection. Water or emulsified oil means the shaft seal has failed.
Motor / Stator ServiceMotor bearings, stator rewind or a replacement motor unit matched to your kW, poles and voltage code.
Level ControllerGrundfos LC level controller for one or two pumps, with the level switches or transmitter to suit your well. Matched to your motor size and starting method.
Complete Replacement PumpWhen a rebuild doesn’t stack up, we quote a like-for-like SE1 from the model on your nameplate.

How we confirm the exact part: Grundfos SE1 kits depend on the free passage, discharge size, motor power and poles. The model reads type, free passage (mm), discharge (DN), kW × 10, poles and voltage code, e.g. SE1.80.100.40.4.50B = 80 mm solids, DN100, 4 kW, 4-pole; 9–30 kW pumps add the range and hydraulic code (e.g. SE1.85.100.150.4.52H). Tick the items above and add a nameplate photo, and we’ll confirm the correct part and price for your exact pump.

Models

Spare parts are available for every SE1 size in the current Grundfos Australia range, and for earlier or non-standard builds (e.g. SE1.100.100.30.4.50B) from the nameplate. The first number after SE1 is the free passage in mm; the second is the discharge size (e.g. SE1.80.100).

SE1.50.65SE1.50.80SE1.80.80SE1.80.100SE1.100.100SE1.100.150SE1.75.100SE1.80.100 (9–30 kW)SE1.85.100SE1.85.150SE1.95.100SE1.95.150SE1.110.200

Models & Key Specifications

Model groupMotor (kW)PolesDischargeFree passage
SE1.50.652.2–42DN6550 mm
SE1.50.802.2–42DN8050 mm
SE1.80.801.5–7.54DN8080 mm
SE1.80.1001.5–7.54DN10080 mm
SE1.100.1004–7.54DN100100 mm
SE1.100.1504–7.54DN150100 mm
SE1.75.10013–18.52DN10075 mm
SE1.80.100 (52S)20–26.52DN10080 mm
SE1.85.100 / .15010–18.54DN100 / DN15085 mm
SE1.95.100 / .15020–224DN100 / DN15095 mm
SE1.110.20010–224DN200110 mm

All sizes: dry or submerged installation with cooling jacket, liquid temperature 0 °C to +40 °C, 50 Hz. 1.5–7.5 kW: 3 × 380–415 V DOL, pH 4–10, thermal switches to 3 kW and thermistors from 4 kW, explosion-proof sensor versions on SE1.50.65. 10–26.5 kW: 3 × 380–415/660–690 V, pH 6.5–14, moisture switch, leakage switch and PTC thermistors, explosion-proof on request. Wet-well only version: see Grundfos SL1; SuperVortex: see Grundfos SEV.

Troubleshooting

Pump blocked or ragging

Likely cause: rags and wipes caught on the impeller leading edge, or an opened-up clearance between the impeller and the wear ring. Action: isolate the power, lift the pump and clear the inlet and impeller; check and reset the impeller clearance and replace the wear ring if it is worn. Frequent ragging on a worn pump is the usual sign a wear ring kit is due.

Moisture alarm or leaking at the shaft seal

Likely cause: worn seal faces letting water into the oil chamber, often from grit, dry running or age; the moisture switch (or WIO sensor) trips the pump before the motor floods. Action: check the oil in the seal chamber: water or emulsified oil means the seal has failed. Fit the shaft seal kit, renew the O-rings and refill with fresh oil. Don’t reset and run on a moisture alarm.

Thermal trip or overheating

Likely cause: an overload from a blocked or worn impeller, a phase fault, too many starts per hour, a dry-installed pump with a blocked cooling jacket. Action: check the voltage on all phases and the motor current against the nameplate; clear the hydraulic end; check level settings so the pump stays submerged or, on dry installs, that the cooling jacket is clear. Repeated trips need a motor inspection.

Low flow or head

Likely cause: wrong rotation, air trapped in the pump, a partly blocked discharge or non-return valve, or wear at the impeller and wear ring. Action: check rotation on three-phase pumps; vent the pump and clear the discharge, valve and auto-coupling; if output still falls short, replace the worn hydraulic parts.

Noise or vibration

Likely cause: solids caught in the impeller, a damaged impeller, worn motor bearings, or the pump not seated properly on the auto-coupling. Action: clear and inspect the impeller; check that the pump sits fully on the auto-coupling base and the guide rails are straight; worn bearings need a motor overhaul.

Pump will not start

Likely cause: no supply, a tripped motor protection, a failed level switch, or a seized pump. Action: check the supply, controller and level switches and reset the protection; with the power isolated, check the impeller turns freely. A seized pump needs inspection of the hydraulic end and bearings.

Damaged cable or water in the cable entry

Likely cause: a cut, crushed or chafed cable from lifting or debris, or a perished cable entry seal. Action: isolate the pump and test the insulation resistance; never splice a submersible cable in the well. Replace the cable kit and cable entry seal, and lift the pump by its chain, never the cable.

Request for Quotation

Selected Parts:

  • No parts selected

Not sure which parts? Just send a photo of the nameplate or part below.

Your pump

Please select your pump model (or choose “Not sure”)

Your details

Please enter your full name
Please enter a valid email address
Please enter a valid phone number

Your enquiry

Please select what you need

Drag & drop image here or tap to browse

JPG, PNG or PDF, max 5MB

File must be smaller than 5MB

Delivery

Please select when you need it
Please enter the delivery suburb or town
Please enter a 4-digit postcode
Postcode and state don't match - please check
Please select a state
Please select a delivery type

We use these details only to prepare and follow up your quote. See our Privacy Policy.

We aim to respond within one business day