Select Qty Ref. Part Number Description Material / Spec
Wear & Consumable Parts
12200RR CP800 2200Stator (Nitrile - Standard)Nitrile rubber (standard)
12200RA CP800 2200Stator (Natural Rubber)Natural rubber
12200RJ CP800 2200Stator (High Nitrile)High nitrile rubber
12500SF CP800 2520Rotor (316 / HCP - Standard)316 stainless, hard chrome plated
12500SF CP800 2500Rotor (316 Stainless)316 stainless steel
12500SB CP800 2520Rotor (431 / HCP)431 stainless, hard chrome plated
12500SB CP800 2500Rotor (431 Stainless)431 stainless steel
12500SF SWP800 2500Rotor (Solar)Solar pump application
11050OO CP800 1060Mechanical Seal Assembly (Standard)Ceramic / carbon
Drive & Motor
10200CPE1251CSMMotor 240V Single-Phase1.25 kW, thermal overload
10200CPE1253MMotor 415V Three-Phase1.25 kW
Wet End — Body & Castings
10100AC CP800 0100Pump BodyCast aluminium main casing
12400AC CP800 2400End CoverCast aluminium end plate
16200AL CP800 6200Support FootAluminium mounting foot
14200RR CP800 4200ThrowerShaft protection disc
13100RR CP800 3110O-RingBody seal ring
10400OO CP00 0430Plug, Nylon (Hex Head 1/4" BSPT)Fill plug
10600AL CP25 0610Nameplate–
Fasteners & Hardware
4P103K113290FBolt (P103)Hex head
2P104K113260FBolt (P104)Hex head
4P105K113280FBolt (P105)Hex head
4P106K113300FBolt (P106)Hex head
24P107W113051FWasher (P107)Flat washer
16P108W113251FSpring Washer (P108)Lock washer
12P109N113100FNut (P109)Hex nut

OEM part numbers are referenced for identification purposes only. Parts listed suit the Mono CP800 ELEC (close-coupled electric) build. Bare-shaft (B/S) drive components are available on request.

OEM part numbers are referenced for identification purposes only.
All parts listed are suitable for use in Mono CP800 pumps.

Exploded Parts Views 

Exploded view shown for reference only. Part numbering may vary by configuration.

Key Technical Specifications 

Parameter Value
Model / Curve CP800 Progressive Cavity Pump
Operating Speed 1450 RPM (standard), 800-1500 RPM with frequency controller
Rated Power 1.25 kW (1.68 HP)
Voltage / Frequency 240V Single-Phase / 415V Three-Phase, 50Hz
Suction / Discharge Connection 3" Suction / 1.5" BSP Discharge
Maximum Suction Lift 6 metres
Maximum Temperature 80°C
Impeller Type Progressive Cavity (Helical Rotor/Stator)
Rotation Direction Clockwise (viewed from shaft end)
Shaft Diameter 24mm with 8 x 7mm key
Installation Type Horizontal Baseplate Mounted (suction port vertical)

Troubleshooting, Common Faults & Solutions

Motor Will Not Run

Likely Cause: Thermal overload tripped, blown fuse/power failure, motor defect, or faulty pressure switch (pressure system)

Action / Part: Reset thermal overload (red button on capacitor box for single-phase), check electrical supply and fuses, verify pressure switch operation, test motor windings

No Liquid Delivered / Pump Will Not Prime

Likely Cause: Pump not filled before starting, air leak on suction, discharge head too high, suction lift too high, inlet pipe not submerged, or damaged stator/rotor

Action / Part: Fill pump with liquid through plug (OO CP00 0430) adjacent to suction port, check all suction line joints for air leaks, verify suction lift is within 6 metre maximum, ensure inlet pipe adequately submerged, replace stator (RR CP800 2200) and/or rotor (SF CP800 2520) if worn

Not Enough Liquid Delivered

Likely Cause: Air leak on suction, discharge head too high, suction lift too high, inlet pipe not submerged, or viscosity greater than rating

Action / Part: Check all suction connections for air leaks, verify system head within pump rating, reduce suction lift, increase inlet pipe submersion depth, heat product to reduce viscosity if too thick

Loss of Liquid After Starting

Likely Cause: Air or gas in liquid, air leak on suction, insufficient net inlet head, or blocked inlet

Action / Part: Check for air entrainment in pumped liquid, inspect suction line for leaks, increase suction head, clear inlet blockage including foot valve/strainer

Pump is Noisy (Cavitation)

Likely Cause: Air or gas in liquid, blocked foot valve/strainer, restriction in line, or excessive suction lift

Action / Part: Eliminate air entrainment, clean foot valve and strainer, remove restrictions in suction line, reduce suction lift below 6 metre maximum

Pump Vibrates

Likely Cause: Cavitation (see above) or pump not bolted down firmly

Action / Part: Address cavitation issues, secure all pump mounting bolts firmly to baseplate, check support foot (AL CP800 6200) mounting

Pump Will Not Give Rated Pressure

Likely Cause: Worn stator, rotor, or both

Action / Part: Replace stator (RR CP800 2200) and rotor (SF CP800 2520) - always replace together as matched set, check mechanical seal (OO CP800 1060) condition

Motor Runs Hot

Likely Cause: Viscosity greater than rating, voltage/frequency differ from rating, thermal overload set too low, motor defect, or pump overloaded

Action / Part: Note: Motor normally runs too hot to hold. Reduce product viscosity, verify voltage matches motor rating (240V or 415V), adjust thermal overload setting (three-phase), check motor current draw, verify motor (CPE1251CSM for 240V, CPE1253M for 415V)

Thermal Overload Trips Out

Likely Cause: Low voltage, too frequent starting (single-phase), overload set too low (three-phase), pump overloaded, or motor not protected from sun

Action / Part: Verify voltage at motor terminals, reduce start/stop frequency, adjust thermal overload setting, check current draw against motor rating, provide motor shade/ventilation

Pump Starts Too Often (Pressure System)

Likely Cause: Incorrect pressure switch setting, leaking non-return valve, leak in system, pressure tank too small, or air pre-charge too low

Action / Part: Adjust pressure switch cut-in/cut-out settings, replace non-return valve, repair system leaks, install larger pressure tank, check/adjust pressure tank air pre-charge, inspect air bag in pressure tank

Incorrect Rotation (Three-Phase)

Likely Cause: Three-phase wiring incorrect

Action / Part: CRITICAL: Remove pump from motor before checking direction. Running pump in reverse can cause rotor to unscrew from motor shaft causing severe damage. Correct rotation is clockwise viewed from shaft end. If incorrect, swap any two of the three-phase supply wires

Request for Quotation

Selected Parts:

  • No parts selected

Not sure which parts? Just send a photo of the nameplate or part below.

Your details

Please enter your full name
Please enter a valid email address
Please enter a valid phone number

Your enquiry

Please select what you need

Drag & drop image here or tap to browse

JPG, PNG or PDF, max 5MB

File must be smaller than 5MB

Delivery

Please select when you need it
Please enter the delivery suburb or town
Please enter a 4-digit postcode
Postcode and state don't match - please check
Please select a state
Please select a delivery type

We use these details only to prepare and follow up your quote. See our Privacy Policy.

We aim to respond within one business day

Mono CP800 spare parts: frequently asked questions

What spare parts are listed for the Mono CP800?

The list covers stators, rotors and the mechanical seal, the 240 V and 415 V motors, the pump body, end cover, support foot, thrower, O-ring and fill plug, plus fasteners. The parts suit the CP800 ELEC (close-coupled electric) build. Bare-shaft drive components are available on request.

What stator and rotor options are available for the CP800?

Stators are listed in nitrile (standard), natural rubber and high nitrile. Rotors are listed in 316 stainless with hard chrome plating (standard), plain 316 stainless, 431 stainless with or without hard chrome, and a solar-application rotor. Tell us your fluid on the quote form and we'll confirm the right combination.

Should I replace the CP800 rotor and stator together?

Yes. If the pump won't reach its rated pressure, the usual cause is a worn stator, rotor or both. The troubleshooting guide on this page says to replace the stator and rotor together as a matched set and to check the condition of the mechanical seal at the same time.

How do I make sure I order the right CP800 parts?

Tick the parts you need and your selection carries into the quote form. If you're unsure of a part or your exact build, add a photo of the pump or nameplate and we'll identify it before quoting. Running a larger unit? See the Mono CP1600 spare parts page, or browse all Mono pump spare parts.