Mono Epsilon E17B Pump
Spare Parts for Epsilon E17B Pump
Product Summary
The Mono Epsilon E17B is a robust two-stage progressive cavity pump designed for heavy-duty industrial applications. Featuring advanced flexishaft drive technology and precision-engineered components, this pump delivers reliable performance for demanding fluid transfer operations requiring high pressure and consistent flow rates.
- Flexishaft Drive System: Stainless steel flexible shaft provides smooth torque transmission with zero maintenance requirements, eliminating traditional universal joint wear points
- Two-Stage Design: Twin-cavity configuration delivers higher pressure capabilities (up to 24 bar) while maintaining smooth, pulsation-free flow characteristics
- Exceptional Suction Lift: Self-priming design achieves suction lift exceeding 8 metres, ideal for installations where pump positioning above liquid level is required
- Bi-Directional Operation: Capable of reversible rotation for special applications, offering operational flexibility and system versatility
- Heavy-Duty Construction: Cast iron or stainless steel casing options with precision-machined components ensure long service life in abrasive and corrosive environments
Spare Parts List
Item = exploded-diagram reference from the Mono Epsilon manual (OMMP/034/03). Ordered by pump model + item. This page is for the Mono Epsilon E17B. The mechanical seal carries the real OEM part number for this model's shaft size.
| Select | Qty | Item | Part Number | Description | Material / Spec |
|---|---|---|---|---|---|
| 1 | 22A | 22A | Stator (specify elastomer) | E17B stator 34.27 kg; nitrile std / others to suit fluid | |
| 1 | 25A | 25A | Rotor | E17B rotor 27.1 kg; hard-chrome / stainless | |
| 1 | 26A | 26A | Flexishaft | E17B flexishaft 4.4 kg | |
| 1 | 27A | 27A | Drive Clamp | - | |
| 2 | 27B | 27B | Drive Clamp Pin | - | |
| 1 | 29C | 29C | Shaft Pin | - | |
| 1 | 32A | 32A | Drive Shaft | E17B shaft 4.3 kg | |
| 1 | 10A | M065139G | Mechanical Seal (DIN L1K, 65mm shaft) | OEM seal M065139G | |
| 1 | 65A | 65A | Mechanical Seal Carrier / Gland Selection | - | |
| 1 | 10B | 10B | Rotary Shaft Lipseal (optional) | - | |
| 1 | 66A | 66A | Abutment Ring | - | |
| 2 | 75A | 75A | Sleeve (shaft protection) | - | |
| 1 | 01A | 01A | Pump Body | - | |
| 1 | 06A | 06A | Adaptor | - | |
| 1 | 76A | 76A | Adaptor Flange | - | |
| 1 | 23A | 23A | Suction Chamber | - | |
| 1 | 23B | 23B | Suction Chamber Extension (Inspection Port) | - | |
| 1 | 23C | 23C | Suction Chamber Extension Tube | - | |
| 1 | 24A | 24A | End Cover | - | |
| 1 | 42A | 42A | Thrower | - | |
| 1 | 15A | 15A | Thrower Guard | - | |
| 2 | 62A | 62A | Support Foot | - | |
| 1 | 06B | 06B | Nameplate | - | |
| 1 | 20B | 20B | Gasket - Gland | Non-asbestos | |
| 1 | 20D | 20D | Gasket - Suction Chamber / Extension | Non-asbestos | |
| 1 | P401 | P401 | Toroidal Seal Ring | - | |
| 1 | P402 | P402 | Toroidal Seal Ring | - | |
| 1 | P403 | P403 | Toroidal Seal Ring | - | |
| 1 | P404 | P404 | Toroidal Seal Ring | - | |
| 4 | 95A | 95A | Tie Bars - Stator | - | |
| 1 | 95B | 95B | Tie Bars - Suction Chamber Ext Tube | - | |
| 1 | P513 | P513 | Drive Clamp Bolt | - | |
| 1 | P512 | P512 | Clamp Bolt | - | |
| 1 | P104 | P104 | Hex Head Bolt | - | |
| 1 | P106 | P106 | Flat Washer | - | |
| 1 | P107 | P107 | Spring Washer | - | |
| 1 | P109 | P109 | Hex Nut | - | |
| 1 | P201 | P201 | Taper Plug | - | |
| 1 | P202 | P202 | Taper Plug | - |
Item references are from the OEM manual for identification only; weights are guidance per the manual and exact build is confirmed at quote. Associated gland packing, additional washers/nuts and lubricants are available per the manual on request.
Exploded Parts Views
Key Technical Specifications
| Parameter | Value |
|---|---|
| Model / Curve | Epsilon E17B / Two-Stage |
| Rated Power | Varies by application (typically 5.5 - 15 kW) |
| Voltage / Frequency | 240V/415V / 50Hz (other voltages available) |
| Rated Current | Application dependent |
| Discharge Connection | Flanged (size varies by application) |
| Impeller Type | Progressive Cavity (Flexishaft Driven) |
| Installation Type | Horizontal Baseplate Mounted |
Troubleshooting, Common Faults & Solutions
No Discharge from Pump
Likely Cause: Incorrect rotation direction, pump unprimed, or blocked delivery line
Action / Part: Verify motor rotation matches nameplate arrow (bi-directional capable), prime pump with liquid, clear blockages in discharge pipework
Loss of Capacity / Reduced Flow
Likely Cause: Worn rotor/stator elements, insufficient NPSH, air entering suction line, or belt drive slipping
Action / Part: Replace rotor (25A) and/or stator (22A), increase suction head, check gland adjustment for air leaks, re-tension drive belts
Pump Stalls at Start-Up
Likely Cause: Product viscosity too high, low voltage, or flexishaft damage
Action / Part: Heat product to reduce viscosity, verify electrical supply voltage, inspect flexishaft (26A) for visible damage or distortion
Excessive Noise and Vibration
Likely Cause: Misaligned coupling, worn bearings, or insecure pump mounting
Action / Part: Check and adjust alignment to motor/gearbox, replace shaft bearings (lubricate with BP LC2 grease), tighten all baseplate mounting bolts
Excessive Gland or Seal Leakage
Likely Cause: Worn drive shaft, damaged mechanical seal, or inadequate gland flush
Action / Part: Replace drive shaft (32A) if gland area worn, install new mechanical seal assembly (10A - M065139G), ensure proper seal flush fluid flow
Motor Overheats / Excessive Power Draw
Likely Cause: Delivery pressure above rated limit, gland overtightened, or pump speed too high
Action / Part: Check for delivery line blockages, loosen packed gland to allow slight drip, reduce pump speed, verify relief valve setting
Rapid Stator Wear / Premature Failure
Likely Cause: Dry running, abrasive product, or product temperature exceeding rating
Action / Part: Install dry-run protection device, ensure pump always primed before starting, cool product or upgrade to temperature-rated stator material, replace with new stator (22A)
Flexishaft Failure or Damage
Likely Cause: Excessive torque, visible damage to protective coating, or shaft distortion
Action / Part: Replace flexishaft assembly (26A - 4.4 kg), check drive clamp bolts (P513) are torqued to 10 Nm, apply Loctite 5910 to shaft assembly per manual
Request for Quotation