Mouvex Micro C Eccentric Disc Pump

Spare Parts for Mouvex Micro C 125, 250, 500 and 800 Eccentric Disc Pumps

This page lists genuine OEM spare parts for Mouvex pumps.
Pump Spares Direct is an independent supplier and is not affiliated with, endorsed by, or authorised by Mouvex or PSG.

Image shown for pump identification purposes only.

DOWNLOAD DATASHEET

Product Summary

Genuine OEM spare parts for Mouvex Micro C 125, 250, 500 and 800 compact hygienic eccentric disc pumps, used for precise transfer of cosmetics, pharmaceuticals and food products. Seal sets, the piston and cylinder for each size, transmissions and main parts are listed below by their Mouvex reference.

Type: compact hygienic eccentric disc pump Sizes: Micro C 125, 250, 500, 800 Max speed 1000 rpm Max diff. 15 bar (125) to 3 bar (800) Parts: Mouvex PL 1001-P01

Spare Parts List

✓ Tick the parts you need. References are as printed in the Mouvex parts list for this model; material and build options (FKM or FEP-FKM seals, heat-jacketed HT versions, bushing type) each have their own reference. Not sure? Add a nameplate photo and we’ll match the parts for you.

SelectPart (as printed by Mouvex)Mouvex reference
Service kits & seal sets
Cylinder and Piston Set MC125 (Micro C 125)Ref. AUX313836 · maintenance kit · wear part · PL 1001-P01
Set of FEP-FKM O-Ring SealsRef. AUX313840 · maintenance kit · PL 1001-P01
Set of FKM O-Ring SealsRef. AUX313839 · maintenance kit · wear part · PL 1001-P01
ScrewRef. AUX224186 · Qty 4 · maintenance kit · PL 1001-P01
Complete TransmissionRef. AUX313817 · maintenance kit · wear part · PL 1001-P01
Cylinder and Piston Set MC250 (Micro C 250)Ref. AUX313837 · maintenance kit · wear part · PL 1001-P01
Cylinder and Piston Set MC500 (Micro C 500)Ref. AUX313838 · maintenance kit · wear part · PL 1001-P01
Cylinder and Piston Set MC800 (Micro C 800)Ref. AUX314448 · maintenance kit · wear part · PL 1001-P01
Main parts
Piston ScrewRef. AUX224792 · PL 1001-P01
Front Cover Plate 1 2" BSPRef. AUX313834 · PL 1001-P01
Front Cover Plate 1 2" NPTRef. AUX313835 · PL 1001-P01
Front Cover Plate Clamp Asme BpeRef. AUX316486 · PL 1001-P01
Front Cover Plate Clamp DIN 32676Ref. AUX313833 · PL 1001-P01
Front Cover Plate Clamp ISO25Ref. AUX314047 · PL 1001-P01
Front Cover Plate DIN20Ref. AUX313832 · PL 1001-P01
Front Cover Plate SMS25Ref. AUX313919 · PL 1001-P01

How we confirm the exact part: Mouvex spares are ordered by their reference number against the pump build shown on the nameplate (model, serial number and options code). References on this page are as printed in the current Mouvex parts list. Send the nameplate details or a photo, and tell us the liquid pumped, and we’ll confirm the right genuine parts before we quote.

Service Intervals & When to Replace

  • Piston and cylinder: wear parts; replace them when the thickness measurements fall below the values in the Micro C IOM.
  • Bellows: keep the vent open to atmosphere; a closed vent shortens bellows life, and a leak at the vent signals bellows failure.
  • Cleaning: during CIP/SIP the inlet pressure must stay under 2 barg so the piston lifts and cleaning liquid passes through.
  • Storage: turn the pump by hand a few revolutions every two months when it is out of service.

Models

This page covers the Mouvex Micro C. The model, serial number and build options code are on the pump nameplate; Mouvex matches spares to that build.

Micro C 125Micro C 250Micro C 500Micro C 800

Models & Key Specifications

ModelMax differentialDisplacementMax speedParts list
Micro C 12515 bar0.0024 L1000 rpmPL 1001-P01
Micro C 25010 bar0.0045 L1000 rpmPL 1001-P01
Micro C 5005 bar0.0090 L1000 rpmPL 1001-P01
Micro C 8003 bar0.0133 L1000 rpmPL 1001-P01

Limits from Mouvex IOM NT 1001-P00: pumped product −15°C to +100°C, CIP/SIP up to +121°C. Rows marked with a size apply to that size only.

Troubleshooting

No flow or low flow

Likely cause: Port plugs left in, wrong rotation or speed too low; a bypass set below the discharge pressure or not closing; or internal wear. Action: Check the drive, rotation and speed, then measure discharge pressure. If it is low, reset or clean the bypass; if the pump is worn, replace the piston and cylinder (as a matched pair).

High vacuum at the inlet, pump noisy

Likely cause: Suction lift or suction losses too high, a blocked inlet (valve, strainer, blank seal) or product vapour pressure too high for the temperature. Action: Lower the pump or shorten and enlarge the suction line, clear the strainer and valves, and cool the product or bring the pump closer to the tank.

Low vacuum and poor priming

Likely cause: Air leaking in at the front cover seals or flanges, the bypass not seating, or internal wear. Action: Isolate the pump from the suction line and re-measure the vacuum. Replace the seal set, clean the bypass seat, or replace the piston and cylinder (as a matched pair) if the pump itself will not pull vacuum.

Bearings running hot

Likely cause: Pipework pulling on the pump flanges, poor pump-to-drive alignment, a twisted baseplate or excessive belt or chain tension. Action: Support the pipework so it does not load the pump, re-check coupling alignment at each installation stage, and make sure the baseplate sits on its mounting points.

Motor overloads or trips

Likely cause: Viscosity, specific gravity or head losses higher than the pump was selected for, speed too high, misalignment or a motor wiring fault. Action: Check the actual discharge pressure against the duty, reduce speed or heat the product, and check alignment and motor connections. Do not use the bypass as a flow control.

Request for Quotation

Selected Parts:

  • No parts selected

Not sure which parts? Just send a photo of the nameplate or part below.

Your pump

Please select your Mouvex model (or choose “Not sure”)

Your details

Please enter your full name
Please enter a valid email address
Please enter a valid phone number

Your enquiry

Please select what you need

Drag & drop image here or tap to browse

JPG, PNG or PDF, max 5MB

File must be smaller than 5MB

Delivery

Please select when you need it
Please enter the delivery suburb or town
Please enter a 4-digit postcode
Postcode and state don't match - please check
Please select a state
Please select a delivery type

We use these details only to prepare and follow up your quote. See our Privacy Policy.

We aim to respond within one business day

Mouvex Micro C spare parts: frequently asked questions

Tap a question to see the answer.

What spare parts are listed for the Mouvex Micro C?

The page lists maintenance kits and seal sets first, then wear parts, then the main parts, each with the Mouvex reference printed in PL 1001-P01. Material versions such as FKM, FEP-FKM or CVT seals have their own references.

How do I order the right Mouvex parts?

Mouvex matches spares to the pump build. Tick the parts you need, choose your model in the quote form, and add a nameplate photo showing the model, serial number and options code, plus the liquid pumped. We confirm the exact genuine parts before quoting.

Which Micro C size do I have, and what are its limits?

The size is on the nameplate: Micro C 125, 250, 500 or 800. Mouvex rates them at 15, 10, 5 and 3 bar differential respectively, all at up to 1000 rpm. The piston and cylinder are size-specific, so the size matters when ordering.

Do you supply parts for other Mouvex pumps?

Yes. We list parts for Mouvex A, C, Micro C, SLC, SLS and FLO eccentric disc pumps and P Series sliding vane pumps. See our Mouvex eccentric disc pumps or all Mouvex spare parts by series. Not sure which model you have? Send a nameplate photo.