Genuine OEM spare parts for Mouvex SLS1, SLS2 and SLS3 hygienic eccentric disc pumps for food, dairy, cosmetic and pharmaceutical duties with CIP and SIP cleaning. The three sizes share almost every part, so seal sets, the size-specific piston and cylinder, transmissions and main parts are listed on one page by their Mouvex reference.

Type: hygienic eccentric disc pump, bellows-sealed Models: SLS1, SLS2, SLS3 Max speed 1000 rpm Max diff. 16 / 10 / 6 bar Parts: Mouvex PL 1004-F01

Spare Parts List

✓ Tick the parts you need. References are as printed in the Mouvex parts list for this model; material and build options (FKM or FEP-FKM seals, heat-jacketed HT versions, bushing type) each have their own reference. Not sure? Add a nameplate photo and we’ll match the parts for you.

SelectPart (as printed by Mouvex)Mouvex reference
Service kits & seal sets
Cylinder and Piston Set (SLS1)Ref. AUX314814 · maintenance kit · wear part · PL 1004-F01
Set of CVT O-Ring SealsRef. AUX314821 · maintenance kit · PL 1004-F01
Set of FKM O-Ring SealsRef. AUX314820 · maintenance kit · wear part · PL 1004-F01
Complete Transmission without Bellows Monitoring SystemRef. AUX314797 · maintenance kit · wear part · PL 1004-F01
Complete Transmission with BMS Pressure Switch for Pump with Suction Port in Position 2 or 3 (G) – ATEXRef. AUX315275 · maintenance kit · wear part · PL 1004-F01
Complete Transmission with BMS Pressure Switch for Pump with Suction Port in Position 2 or 3 (G)Ref. AUX315685 · maintenance kit · wear part · PL 1004-F01
Complete Transmission with BMS Pressure Switch for Pump with Suction Port in Position 1 (D) – ATEXRef. AUX315806 · maintenance kit · wear part · PL 1004-F01
Complete Transmission with BMS Pressure Switch for Pump with Suction Port in Position 1 (D)Ref. AUX315805 · maintenance kit · wear part · PL 1004-F01
Cylinder and Piston Set (SLS2)Ref. AUX314815 · maintenance kit · wear part · PL 1004-F01
Cylinder and Piston Set (SLS3)Ref. AUX314816 · maintenance kit · wear part · PL 1004-F01
Wear parts
BreatherRef. AUX211144 · wear part · PL 1004-F01
Bearing Gaskets and Screws SetRef. AUX315025 · wear part · PL 1004-F01
Main parts
Piston NutRef. AUX226535 · PL 1004-F01
Not Polished Front Cover Connection Clamp Asme Bpe 38Ref. AUX318584 · PL 1004-F01
Polished Front Cover Connection Clamp Asme Bpe 38Ref. AUX318588 · PL 1004-F01
Not Polished Front Cover Connection Clamp ISO 38Ref. AUX314874 · PL 1004-F01
Not Polished Front Cover Flange Aseptik DIN 11864-BF-A DN40Ref. AUX314886 · PL 1004-F01
Not Polished Front Cover Connection DIN 40Ref. AUX314870 · PL 1004-F01
Polished Front Cover Connection Clamp ISO 38Ref. AUX314875 · PL 1004-F01
Polished Front Cover Flange Aseptik DIN 11864-BF-A DN40Ref. AUX314887 · PL 1004-F01
Polished Front Cover Connection DIN 40Ref. AUX314871 · PL 1004-F01
Polished Front Cover Connection SMS 38Ref. AUX314881 · PL 1004-F01
Not Polished Front Cover Connection SMS 38Ref. AUX314880 · PL 1004-F01

How we confirm the exact part: Mouvex spares are ordered by their reference number against the pump build shown on the nameplate (model, serial number and options code). References on this page are as printed in the current Mouvex parts list. Send the nameplate details or a photo, and tell us the liquid pumped, and we’ll confirm the right genuine parts before we quote.

Service Intervals & When to Replace

  • Bellows: a leak at the vent signals bellows failure; keep the vent open to atmosphere, as a closed vent shortens bellows life.
  • Piston and cylinder: wear parts; replace them as a pair when output drops or they reach the IOM minimum dimensions.
  • Transmission oil: with Mouvex CS05 oil, drain every 24,000 h at or below 80°C, 12,000 h at 80–100°C and 6,000 h at 100–110°C.
  • Cleaning: keep CIP/SIP inlet pressure within the IOM limit (3 barg) so the piston lifts and the cleaning flow passes through the pump.

Models

This page covers the Mouvex SLS1, SLS2 and SLS3. The model, serial number and build options code are on the pump nameplate; Mouvex matches spares to that build.

SLS1SLS2SLS3

Models & Key Specifications

ModelMax differentialDisplacementMax speedParts list
SLS116 bar0.017 L1000 rpmPL 1004-F01
SLS210 bar0.034 L1000 rpmPL 1004-F01
SLS36 bar0.051 L1000 rpmPL 1004-F01

Limits from Mouvex IOM NT 1004-F00: pumped product −15°C to +110°C, CIP/SIP up to +121°C, jacket up to 5 barg. Rows marked with a size apply to that size only.

Troubleshooting

No flow or low flow

Likely cause: Port plugs left in, wrong rotation or speed too low; a bypass set below the discharge pressure or not closing; or internal wear. Action: Check the drive, rotation and speed, then measure discharge pressure. If it is low, reset or clean the bypass; if the pump is worn, replace the piston and cylinder (as a matched pair).

High vacuum at the inlet, pump noisy

Likely cause: Suction lift or suction losses too high, a blocked inlet (valve, strainer, blank seal) or product vapour pressure too high for the temperature. Action: Lower the pump or shorten and enlarge the suction line, clear the strainer and valves, and cool the product or bring the pump closer to the tank.

Low vacuum and poor priming

Likely cause: Air leaking in at the front cover seals or flanges, the bypass not seating, or internal wear. Action: Isolate the pump from the suction line and re-measure the vacuum. Replace the seal set, clean the bypass seat, or replace the piston and cylinder (as a matched pair) if the pump itself will not pull vacuum.

Bearings running hot

Likely cause: Pipework pulling on the pump flanges, poor pump-to-drive alignment, a twisted baseplate or excessive belt or chain tension. Action: Support the pipework so it does not load the pump, re-check coupling alignment at each installation stage, and make sure the baseplate sits on its mounting points.

Motor overloads or trips

Likely cause: Viscosity, specific gravity or head losses higher than the pump was selected for, speed too high, misalignment or a motor wiring fault. Action: Check the actual discharge pressure against the duty, reduce speed or heat the product, and check alignment and motor connections. Do not use the bypass as a flow control.

Request for Quotation

Selected Parts:

  • No parts selected

Not sure which parts? Just send a photo of the nameplate or part below.

Your pump

Please select your Mouvex model (or choose “Not sure”)

Your details

Please enter your full name
Please enter a valid email address
Please enter a valid phone number

Your enquiry

Please select what you need

Drag & drop image here or tap to browse

JPG, PNG or PDF, max 5MB

File must be smaller than 5MB

Delivery

Please select when you need it
Please enter the delivery suburb or town
Please enter a 4-digit postcode
Postcode and state don't match - please check
Please select a state
Please select a delivery type

We use these details only to prepare and follow up your quote. See our Privacy Policy.

We aim to respond within one business day

Mouvex SLS1, SLS2 and SLS3 spare parts: frequently asked questions

Tap a question to see the answer.

What spare parts are listed for the Mouvex SLS1, SLS2 and SLS3?

The page lists maintenance kits and seal sets first, then wear parts, then the main parts, each with the Mouvex reference printed in PL 1004-F01. Material versions such as FKM, FEP-FKM or CVT seals have their own references.

How do I order the right Mouvex parts?

Mouvex matches spares to the pump build. Tick the parts you need, choose your model in the quote form, and add a nameplate photo showing the model, serial number and options code, plus the liquid pumped. We confirm the exact genuine parts before quoting.

Are SLS1, SLS2 and SLS3 parts interchangeable?

Almost. The three sizes share the seal sets, transmissions and most main parts, but each has its own cylinder and piston set, and they are rated at 16, 10 and 6 bar respectively. Check the size on the nameplate before ordering the piston and cylinder.

Do you supply parts for other Mouvex pumps?

Yes. We list parts for Mouvex A, C, Micro C, SLC, SLS and FLO eccentric disc pumps and P Series sliding vane pumps. See our Mouvex eccentric disc pumps or all Mouvex spare parts by series. Not sure which model you have? Send a nameplate photo.