NETZSCH NEMO SH / SA Pumps

Spare Parts for NEMO SH Hygienic and SA Aseptic Progressive Cavity Pumps

This page lists replacement and compatible spare parts for NETZSCH pumps.
Pump Spares Direct is an independent supplier and is not affiliated with, endorsed by, or authorised by NETZSCH.

Image shown for pump identification purposes only.

DOWNLOAD DATASHEET

Product Summary

Genuine and compatible spare parts for the NETZSCH NEMO® SH hygienic and NEMO® SA aseptic progressive cavity pumps with bearing housing and free shaft end, used across Australia in dairy, food, beverage, cosmetic and pharmaceutical plants for gentle transfer with CIP and SIP. Both share the NM015 to NM105 sizes and a dead-space-free flexible rod (the SA adds double seals with a sterile barrier), so tick what you need and we’ll match the exact parts to your nameplate (e.g. NM053 SH or NM053 SA).

Type: Hygienic & aseptic progressive cavity Build: Bearing housing · flexible rod · polished stainless Range: NM015 – NM105 · to 120 m³/h · to 24 bar

Spare Parts List

✓ Tick the parts you need. SH and SA wear parts are matched to pump size, stator elastomer and seal arrangement, so your nameplate model and serial number are all we need to get them right. Not sure which items? Add a photo of the nameplate and we’ll work out the parts for you.

SelectWear / Service ItemFunction & when to replace
Common Service Kits
StatorThe elastomer sleeve the rotor turns in, in FDA-compliant compounds (food-grade NBR, EPDM or FKM, chosen to suit your product and CIP chemicals). Replace when output drops, after any dry running, or if the elastomer has swollen, hardened or torn.
RotorThe polished stainless steel helical rotor. Replace it with the stator if it is worn, scored or pitted, as a rough rotor quickly damages a new stator and holds product residue.
Flexible RodThe dead-space-free flexible rod that replaces conventional joints, flexing to follow the rotor’s eccentric motion. It is wear-free in normal service; replace it if kinked, cracked or damaged by a seizure or over-pressure event.
Mechanical SealSH pumps run a single-acting hygienic seal with a double-acting option; SA pumps use a double-acting seal in tandem with an unpressurised static or dynamic quench. Replace at the first sign of leakage or contaminated quench fluid.
Gasket & O-Ring SetAll static seals in FDA-compliant elastomer, including the double-sealed chambers on SA pumps that carry sterile condensate, steam or detector fluid. Renew whenever the pump is opened.
BearingsBearings and shaft seals in the bearing housing that carry the drive shaft. Replace if noisy, running hot or showing play.
Other Core Parts
Drive ShaftThe shaft running from the bearing housing through the mechanical seal to the flexible rod. Replace if worn at the seal or bearing seats, or bent.
Suction HousingThe crevice-free, polished pump casing on the inlet side. Replace if pitted, cracked or damaged on the seal or connection faces.
Pressure BranchThe discharge end piece at the stator outlet. Replace if damaged, or when changing the connection type.
Quench / Barrier FittingsLines and fittings that supply sterile condensate, steam or detector fluid to the SA barrier chambers and seal quench. Replace if blocked, leaking or damaged.
Clamp / Hygienic Connection SealsSeals and clamps for the hygienic process connections, matched to the fitting standard on your pump. Renew at shutdowns or when they show compression set.
Drive CouplingConnects the free shaft end to the motor or gearbox. Replace if worn, cracked or causing vibration, and re-check alignment.
Gear Motor / DriveThe motor, gear motor or variable-speed drive on the baseplate. We match a replacement to your kW, output speed and frame.
Complete Replacement PumpWhen a rebuild doesn’t stack up, we quote a like-for-like NEMO SH or SA from the model and serial number on your nameplate.

How we confirm the exact part: SH and SA parts depend on pump size, rotor/stator geometry, stator elastomer, seal arrangement (single, double or tandem with quench) and process connections. Your nameplate carries the model (e.g. NM053 SH) and the serial number that identifies the original build. Tick the items above and add a nameplate photo, and we’ll confirm the correct part for your exact pump.

Models

Spare parts are available for every NEMO SH Plus and SA size in the current NETZSCH range, and both versions use the same NM015 to NM105 sizes.

NM015NM021NM031NM038NM045NM053NM063NM076NM090NM105SH Plus (hygienic)SA (aseptic)

Models & Key Specifications

SizeMax. pressureMax. capacityMax. speed
NM015 SH / SA24 bar0.7 m³/h800 rpm
NM021 SH / SA24 bar2 m³/h800 rpm
NM031 SH / SA24 bar5 m³/h600 rpm
NM038 SH / SA24 bar12 m³/h600 rpm
NM045 SH / SA24 bar20 m³/h550 rpm
NM053 SH / SA24 bar30 m³/h550 rpm
NM063 SH / SA24 bar40 m³/h500 rpm
NM076 SH / SA24 bar55 m³/h350 rpm
NM090 SH / SA12 bar80 m³/h300 rpm
NM105 SH / SA12 bar120 m³/h250 rpm

All sizes: wetted materials to FDA and EU 1935/2004, built to the 3-A Sanitary Standard, CIP/SIP capable, bearing housing with free shaft end for any drive type. SA adds double-sealed chambers supplied with sterile condensate, steam or detector fluid.

Troubleshooting

Stator wears quickly or output falls away

Likely cause: dry running at start-up or between batches, abrasive solids, running faster than the product allows, or a worn rotor. Action: never run the pump dry (fit dry-run protection), check the speed suits the product, and replace the rotor and stator together if both are worn.

Stator swollen or hardened after CIP/SIP

Likely cause: the elastomer is not compatible with the product or the cleaning chemicals, or SIP temperatures are above what the compound tolerates. Action: tell us the product, CIP chemicals and SIP temperatures and we’ll check the elastomer choice before supplying a replacement stator.

Leaking at the mechanical seal

Likely cause: dry running, sticky or crystallising product on the faces, thermal shock during CIP/SIP, or perished O-rings. Action: replace the mechanical seal and O-rings; for sticky or critical products consider a double-acting seal.

SA quench fluid discoloured or consumption rising

Likely cause: product leaking past the inner seal into the quench or barrier chamber, or a perished barrier O-ring. Action: stop and inspect the tandem seal and barrier seals, replace them as a set, and flush the quench system before returning to sterile service.

Bearing housing noisy or running hot

Likely cause: worn bearings, poor coupling alignment to the motor, or bearing grease breakdown. Action: check and correct alignment at the drive coupling, replace the bearings and shaft seals, and inspect the coupling.

Pressure spikes or a damaged stator

Likely cause: a closed discharge valve, blocked filter or blocked line. A progressive cavity pump keeps building pressure until something gives. Action: never run against a closed valve; fit a pressure switch or bypass, and inspect the stator, flexible rod and seal after any over-pressure event.

Product residue after cleaning

Likely cause: worn or scored rotor, damaged gaskets leaving crevices, or CIP flow too low. Action: renew the gasket and O-ring set, inspect the rotor surface, and check CIP flow through the pump.

Request for Quotation

Selected Parts:

  • No parts selected

Not sure which parts? Just send a photo of the nameplate or part below.

Your pump

Please select your pump size (or choose “Not sure”)

Your details

Please enter your full name
Please enter a valid email address
Please enter a valid phone number

Your enquiry

Please select what you need

Drag & drop image here or tap to browse

JPG, PNG or PDF, max 5MB

File must be smaller than 5MB

Delivery

Please select when you need it
Please enter the delivery suburb or town
Please enter a 4-digit postcode
Postcode and state don't match - please check
Please select a state
Please select a delivery type

We use these details only to prepare and follow up your quote. See our Privacy Policy.

We aim to respond within one business day