Iwaki LK-F57 Dosing Pump

Spare Parts for LK-F57 Dosing Pump

This page lists replacement and compatible spare parts for Mono pumps.
Pump Spares Direct is an independent supplier and is not affiliated with, endorsed by, or authorised by Iwaki.

Image shown for pump identification purposes only.

Product Summary 

The Iwaki LK-F57 is a high-capacity, mechanically actuated diaphragm metering pump designed for precise chemical dosing in water treatment and industrial processes. Driven by a compact, robust worm-gear reducer and a dual-cam drive mechanism, it ensures long-term reliability and accurate flow control. The pump features a PTFE-faced diaphragm and is available with PVC, PVDF, or Stainless Steel liquid ends to handle aggressive chemicals.

  • Dual-Cam Drive System: Compact and rigid worm gear drive ensures maximum wear resistance and continuous operation durability.
  • High Dosing Accuracy: Maintains a discharge accuracy (repeatability) within ±2% FS with excellent linearity.
  • Mechanical Diaphragm: Nylon-reinforced PTFE diaphragm provides superior chemical resistance and long service life.
  • Outdoor Rated Motor: Standard models employ totally enclosed fan-cooled (TEFC) motors suitable for outdoor installation.
  • Flexible Connections: Available with Flange, Union, or Hose connections to suit various piping systems.

DOWNLOAD DATASHEET

Spare Parts List

Select the required parts below to include them in your quote request.

Select Qty Part Number Description Material / Spec
1 L0167 Diaphragm PTFE / EPDM
2 L0151 Valve Ball (VC Type) Alumina Ceramic
2 L0150 Valve Ball (VH Type) Hastelloy C276
2 L0153 Valve Seat PVC
2 L0152 Valve Guide PVC
2 L0155 Valve Gasket PTFE
1 L1513 Pump Head PVC
1 L0168 Retainer Plate SUS304
2 L0157 O-Ring, Case (VC) FKM (Viton)
2 L0156 O-Ring, Case (VH) EPDM
2 L0161 O-Ring, Adapter (VC) FKM (Viton)
2 L0160 O-Ring, Adapter (VH) EPDM
1 L0794 Oil Seal NBR
1 L1112 Bearing (4T-30203) Steel
2 L0101 Adapter PVC
8 L1168 Hex Bolt with Washer SUS304
1 L0166 Reinforcing Plate Steel
1 L0752 Oil Gauge (3/8") -

OEM part numbers are referenced for identification purposes only.
All parts listed are suitable for use in Mono LK-F57.

Exploded Parts Views 

Exploded view shown for reference only. Part numbering may vary by configuration.

Key Technical Specifications 

Parameter Value
Model / Curve Iwaki LK-F57 (VC/VH)
Rated Power 0.2 kW / 0.25 kW (4-Pole)
Voltage / Frequency 230/400V / 50 Hz (3-Phase)
Rated Current ~1.2 A (Depending on Motor)
Discharge Connection DN20 / DN25 Flange or Union
Impeller Type Mechanical Diaphragm (PTFE)
Installation Type Horizontal / Positive Suction Recommended

Troubleshooting, Common Faults & Solutions

Pump does not start

Likely Cause: Power supply failure or disconnected wiring.

Action / Part: Check voltage and wiring connections. Reset thermal overload if tripped.

Pump operates but no discharge

Likely Cause: Air lock in pump head or suction line blocked.

Action / Part: Release air via air vent valve. Clean Suction Strainer.

Fluctuating discharge quantity

Likely Cause: Debris stuck in valve or worn valve seats.

Action / Part: Clean or replace Valve Balls (L0151) and Seats (L0153).

Liquid leakage from pump head

Likely Cause: Loose head bolts or ruptured diaphragm.

Action / Part: Tighten bolts (L1168) or replace Diaphragm (L0167).

Abnormal noise or vibration

Likely Cause: Worn worm gear or bearings in drive unit.

Action / Part: Inspect/Replace Bearings (L1112) or Oil Seal (L0794).

Online Resources

Alt image
Request for Quotation

Request for Quotation

Thank you!

Your Request for Quote has been successfully sent.
Our team is reviewing your requirements and will be in touch shortly.

Selected Parts:

  • No parts selected
Please enter your full name
Please enter your company name
Please enter a valid email address
Please enter your phone number

Drag & drop image here or click to browse

Accepted formats: JPG, PNG, PDF (Max 5MB)

File size must be less than 5MB
Please select delivery urgency
Please select delivery location
Note on Minimum Orders: A standard minimum order value (MOV) of $1,000 AUD typically applies to process B2B commercial orders efficiently.

We typically respond within 24 hours