Tsurumi HS & HSD Series Single-Phase Drainage Pumps

Spare Parts for Tsurumi HS2.4S to HS3.75SL and HSD2.55S Pumps

This page lists genuine OEM spare parts for Tsurumi pumps.
Pump Spares Direct is an independent supplier and is not affiliated with, endorsed by, or authorised by Tsurumi.

Image shown for pump identification purposes only.

DOWNLOAD DATASHEET

Product Summary

Genuine OEM spare parts for the Tsurumi HS and HSD series, the portable single-phase submersible drainage pumps used for sumps, site drainage and flood response. Mechanical seals, impellers, strainer stands, power cables, packing sets, bearings and motor protectors for five models are listed below with their Tsurumi part numbers.

Type: single-phase drainage pump Models: HS2.4S · HS2.75S · HS3.75S · HS3.75SL · HSD2.55S HSD: high-chrome cast iron impeller Supply: 230 V or 110 V single-phase Seal: double mechanical seal W-14VL

Spare Parts List

✓ Tick the parts you need. Codes are as printed in the Tsurumi parts lists and many are model-specific, so pick your model in the form below. Not sure which model you have? Add a photo of the nameplate and we’ll match the parts for you.

SelectPart (as printed by Tsurumi)Part number & fits
Common Service Kits
Packing & O-Ring SetPart no. 173-550-12 · Fits HS2.4S-53, HSD2.55S-53
Packing & O-Ring SetPart no. 173-003-27 · Fits HS2.75S-52, HS3.75S-52, HS3.75SL-52
Mechanical Seal W-14VL SiC+CCBNPart no. 025-000-82 · Fits HS2.4S-53
Mechanical Seal W-14VL SSiC (ROHS)Part no. 025-000-81 · Fits HS2.75S-52, HS3.75S-52, HS3.75SL-52, HSD2.55S-53
Oil Lifter W-14VL ResinPart no. 030-000-09 · Fits all models on this page
Wear & Consumable Parts
Impeller 50HzPart no. 021-007-43 · Fits HS2.4S-53
Impeller (50HZ) HS Urethane RubberPart no. 021-007-54 · Fits HS2.75S-52, HS3.75S-52
Impeller (50Hz) HS3.75SL-52 Urethane RubberPart no. 021-011-38 · Fits HS3.75SL-52
Impeller (50HZ) HSDA2.55S-52 high-chrome cast ironPart no. 021-009-68 · Fits HSD2.55S-53
Strainer Stand HSA2.4S (ROHS) PVCPart no. 023-002-06 · Fits HS2.4S-53
Strainer Stand HS3.75S PVCPart no. 023-002-08 · Fits HS2.75S-52, HS3.75S-52, HS3.75SL-52
Strainer HSDA2.55S-53/63 SPCPart no. 023-001-66 · Fits HSD2.55S-53
Cabtyre Cable Set (10m) 110V-50HZ(GBR) H07RN3Cx1.5mm2(CEE) LB(HAR)Part no. 001-873-18 · Fits HS2.4S-53
Other Core Parts
Bearing 6201ZZC3Part no. 052-100-15 · Fits all models on this page
Bearing 6202ZZC3Part no. 052-101-16 · Fits HS2.4S-53
Bearing 6302ZZC3Part no. 052-001-06 · Fits HS2.75S-52, HS3.75S-52, HS3.75SL-52, HSD2.55S-53
Motor Protector 110V-60Hz KA142-BBBL21F (T.C)Part no. 053-001-33 · Fits HS2.75S-52, HS3.75S-52, HS3.75SL-52
Motor Protector 110V-50Hz(GBR) KA142-BATL24F (T,C)Part no. 053-002-02 · Fits HSD2.55S-53
Oil Casing HS2.4(S)-51/61 FCPart no. 029-000-58 · Fits HS2.4S-53, HSD2.55S-53
Oil Casing HSA3.75SL/HSA2.75SL FCDPart no. 029-000-74 · Fits HS2.75S-52, HS3.75S-52, HS3.75SL-52

How we confirm the exact part: Part numbers on this page are as printed in the Tsurumi (Europe) parts lists for 50 Hz models, and service guidance is from the Tsurumi operation manual (B-10136-10). Voltage versions of some parts (for example motor protectors) differ, so send the nameplate details or a photo and we’ll confirm the right part before we quote.

Service Intervals & When to Replace

  • Insulation: check the insulation at least once a year or every 3,000 hours. It should be over 20 MΩ; repair or replace the pump if it falls to 10 MΩ.
  • Mechanical seal: if the seal-chamber oil is milky or has water drops, the mechanical seal needs replacing.
  • Packing & O-rings: fit a new set every time the pump is opened.
  • Cable: lift the pump by the handle, never the cable. A damaged cable must be replaced, not repaired.

Models

Covers the HS2.4S, HS2.75S, HS3.75S, HS3.75SL and HSD2.55S. Automatic (HSA) versions share most parts. The model is on the pump nameplate.

HS2.4S-53HS2.75S-52HS3.75S-52HS3.75SL-52HSD2.55S-53

Models & Key Specifications

ModelOutputMax headMax capacityWeightOil
HS2.4S-530.40 kW12.2 m207 L/min11.3 kg160 mL
HS2.75S-520.75 kW18.0 m230 L/min19.0 (230V) / 16.4 (110V) kg160 mL
HS3.75S-520.75 kW18.0 m300 L/min19.6 (230V) / 16.8 (110V) kg160 mL
HS3.75SL-520.75 kW10.8 m580 L/min21.6 (230V) / 19.6 (110V) kg160 mL
HSD2.55S-530.55 kW13.2 m220 L/min14.0 kg160 mL

Figures from the Tsurumi single-phase operating instructions (B-10136-10), 230 V 50 Hz.

Troubleshooting

Pump fails to start

Likely cause: (New/repaired pump) level control not calling, no power, impeller not free, insulation/winding fault; (Pump previously in use) as above, impeller more likely jammed by stone/debris. Action: Check level control is calling for start; Check power is available with multimeter/lamp/tool; Remove pump casing and check impeller rotates freely and quietly; At cable end (never open motor) check earth insulation over 20 M Ohm and winding continuity.

Pump starts but stops

Likely cause: Motor windings or cable damaged; Impeller blocked or choked; Wrong voltage or frequency; Voltage too low; Inexact generator frequency; Liquid of excessive viscosity or density; Wrong setting or thermal overload at power source. Action: Do not open motor; check as above; Check voltage under load.

Pump's head and flow are lower than originally

Likely cause: Restriction in piping or resistance in discharge conduit (too high, too long, too small, too dirty inside); Impeller worn, partially choked or severely narrowed by hard deposits; Strainer or inlet blocked; Pump draws air, or liquid partly volatile or high gas content. Action: Correct the listed cause (manual gives causes only).

Pump generates noise or vibration

Likely cause: Impeller severely damaged, or bearing damaged; Pump lying on its side and drawing a little air. Action: Repair at once; High wear rate likely - reposition pump.

Request for Quotation

Selected Parts:

  • No parts selected

Not sure which parts? Just send a photo of the nameplate or part below.

Your pump

Please select your HS / HSD model (or choose “Not sure”)

Your details

Please enter your full name
Please enter a valid email address
Please enter a valid phone number

Your enquiry

Please select what you need

Drag & drop image here or tap to browse

JPG, PNG or PDF, max 5MB

File must be smaller than 5MB

Delivery

Please select when you need it
Please enter the delivery suburb or town
Please enter a 4-digit postcode
Postcode and state don't match - please check
Please select a state
Please select a delivery type

We use these details only to prepare and follow up your quote. See our Privacy Policy.

We aim to respond within one business day