Product Summary
Genuine OEM spare parts for the Tsurumi KRSU822-51, the 22 kW large-solids version of the KRS heavy-duty dewatering pump. The mechanical seal, oil seal, oil lifter, bearings and motor protector are listed below with their Tsurumi part numbers, and the impeller and wear parts are quoted against your nameplate.
Spare Parts List
✓ Tick the parts you need. Codes are as printed in the Tsurumi parts lists and many are model-specific, so pick your model in the form below. Not sure which model you have? Add a photo of the nameplate and we’ll match the parts for you.
| Select | Part (as printed by Tsurumi) | Part number & fits |
|---|---|---|
| Common Service Kits | ||
| Mechanical Seal H-45X(E) SIC | Part no. 025-000-62 · Fits KRSU822-51 | |
| Oil Seal TC-709212 NBR | Part no. 026-117-14 · Fits KRSU822-51 | |
| Oil Lifter H-45 Resin | Part no. 030-140-19 · Fits KRSU822-51 | |
| Other Core Parts | ||
| Bearing 6309ZZC3 | Part no. 052-001-08 · Fits KRSU822-51 | |
| Bearing 6314ZZD2C3 | Part no. 052-145-12 · Fits KRSU822-51 | |
| Motor Protector KA315-JNAL00 | Part no. 053-285-18 · Fits KRSU822-51 | |
How we confirm the exact part: Part numbers on this page are as printed in the Tsurumi (Europe) parts lists for 50 Hz models, and service guidance is from the Tsurumi operation manual (B-10140-10). Voltage versions of some parts (for example motor protectors) differ, so send the nameplate details or a photo and we’ll confirm the right part before we quote.
Service Intervals & When to Replace
- Mechanical seal: check the oil every 6 months or 3,000 hours. If it is milky or has water in it, the mechanical seal is letting water in and needs replacing.
- Oil: change it every 12 months or 6,000 hours with turbine oil VG32 (non-additive), to the volume in the table above.
- Packing & O-rings: fit a new set every time the pump is opened or inspected.
- Impeller & suction cover: a clear drop in head or flow usually means a worn impeller or a blocked strainer. Worn impellers have sharp edges, so handle with gloves, and check the impeller turns freely without rubbing after refitting.
- Overhaul: Tsurumi recommends a full overhaul every 2 to 5 years, even if the pump seems fine.
Models
This page covers the KRSU822-51. For other KRS models see the KRS and KRS2 pages. The model is on the pump nameplate.
Models & Key Specifications
| Model | Output | Max head | Max capacity | Weight | Oil |
|---|---|---|---|---|---|
| KRSU822-51 | 22 kW | 26.5 m | 5750 L/min | 417 kg | 6500 mL |
Figures from the Tsurumi 3-phase operating instructions (B-10140-10), 400 V 50 Hz. Weight is dry weight; oil is turbine oil VG32.
Troubleshooting
Pump fails to start
Likely cause: Pump new/repaired and tested: supply voltage may not match rating plate; earth insulation or winding continuity fault; Pump previously in satisfactory use: as above, plus impeller jammed (stone, debris, rust between impeller blades and suction cover after long disuse). Action: Check applied voltage agrees with rating plate; At cable free end (never open motor) check earth-lead insulation (over 20 M Ohm) and winding continuity; on 3-phase check the three winding ohm values are within ±10%; Check impeller is free.
Pump starts but stops immediately, causing the motor protector to actuate
Likely cause: Motor windings or cable damaged; Impeller blocked or choked; If pump is new, wrong voltage or frequency; Voltage too low (most common cause); Inexact frequency from diesel generator; Wrong direction of rotation; Liquid of too high viscosity or density; Wrong setting of thermal overload unit. Action: Do not open motor; check insulation/continuity as above; Check supply voltage under load; Correct rotation, overload setting, supply.
The pump's head and pumping volume is lower
Likely cause: Wrong direction of rotation; Piping resistance too high; Impeller worn, partially choked or severely narrowed by hard deposits; Strainer or inlet blocked; Pump draws air, or liquid is partly volatile or contains high level of gas in solution. Action: Correct the listed cause (manual gives causes only).
The pump generates noise or vibration
Likely cause: Wrong direction of rotation; Solid object (stone, etc.) in volute; Impeller severely damaged, or bearing damaged; Pump lying on its side and drawing a little air. Action: Repair damaged impeller/bearing at once; High wear rate likely if pump lies on side drawing air - reposition.