Ebsray RB10 and R10 LPG Pumps

Spare Parts for Ebsray RB10 and R10 Regenerative Turbine LPG Pumps

This page lists genuine OEM spare parts for Ebsray pumps.
Pump Spares Direct is an independent supplier and is not affiliated with, endorsed by, or authorised by Ebsray or PSG.

Image shown for pump identification purposes only.

DOWNLOAD DATASHEET

Product Summary

Genuine OEM spare parts for the Ebsray RB10 and the earlier R10 regenerative turbine pumps, which draw LPG from underground or semi-buried tanks for driveway dispensing, bulk filling, cylinder filling and forklift refuelling. Seals, impellers, bearings and O-rings are listed for each model by the Cat # in its Ebsray IOM.

Type: regenerative turbine pump Models: RB10, R10 (legacy) RB10: up to 140 L/min, 11 bar diff. Driveway dispensing up to 6 hoses Parts: Ebsray IOMs 1069-10 & 1046-02

Spare Parts List

✓ Tick the parts you need. Items are listed by the Cat # printed in each Ebsray IOM parts list, so pick the section for your pump type. Ebsray matches spares to the pump serial number on the nameplate, so add a nameplate photo and we’ll confirm the exact parts.

SelectPart (as printed by Ebsray)Cat # & reference
RB10 (IOM 1069-10)
Seal SeatCat 40 · Qty 1 · IOM 1069-10
Rotary Seal FaceCat 41 · Qty 1 · IOM 1069-10
Seal SleeveCat 42 · Qty 1 · IOM 1069-10
Drive Pin - Seal SleeveCat 44 · Qty 1 · IOM 1069-10
Seal SpringCat 45 · Qty 6 · IOM 1069-10
Second Stage ImpellerCat 3 · Qty 1 · IOM 1069-10
Throttle BushCat 28 · Qty 1 · IOM 1069-10
First Stage ImpellerCat 62 · Qty 1 · IOM 1069-10
DiffuserCat 63 · Qty 1 · IOM 1069-10
Neck RingCat 64 · Qty 1 · IOM 1069-10
Cover BearingCat 65 · Qty 1 · IOM 1069-10
Impeller Housing Bearing - First StageCat 66 · Qty 1 · IOM 1069-10
Bearing - Inspection EndCat 23 · Qty 1 · IOM 1069-10
Bearing - Drive EndCat 24 · Qty 1 · IOM 1069-10
O Ring - CoverCat 4 · Qty 1 · IOM 1069-10
O Ring - BracketCat 26 · Qty 1 · IOM 1069-10
O Ring - ShaftCat 46 · Qty 1 · IOM 1069-10
O Ring - Seal SleeveCat 47 · Qty 1 · IOM 1069-10
O Ring - Seal SeatCat 48 · Qty 1 · IOM 1069-10
O-Ring - Suction ManifoldCat 71 · Qty 1 · IOM 1069-10
O-Ring - First Stage Impeller HousingCat 72 · Qty 1 · IOM 1069-10
GasketCat 79 · Qty 2 · IOM 1069-10
Vent ValveCat 90 · Qty 1 · IOM 1069-10
BodyCat 1 · Qty 1 · IOM 1069-10
CoverCat 2 · Qty 1 · IOM 1069-10
ShaftCat 21 · Qty 1 · IOM 1069-10
Impeller Housing - First StageCat 60 · Qty 1 · IOM 1069-10
R10 – legacy model (IOM 1046-02)
Seal SeatCat 40 · Qty 1 · IOM 1046-02
Rotary Seal FaceCat 41 · Qty 1 · IOM 1046-02
Seal SleeveCat 42 · Qty 1 · IOM 1046-02
Drive Pin - Seal SleeveCat 44 · Qty 3 · IOM 1046-02
Seal SpringCat 45 · Qty 6 · IOM 1046-02
ImpellerCat 3 · Qty 1 · IOM 1046-02
Throttle BushCat 28 · Qty 1 · IOM 1046-02
Bearing - Inspection EndCat 23 · Qty 1 · IOM 1046-02
Bearing - Drive EndCat 24 · Qty 1 · IOM 1046-02
O Ring - CoverCat 4 · Qty 1 · IOM 1046-02
O Ring - BracketCat 26 · Qty 1 · IOM 1046-02
O Ring - ShaftCat 46 · Qty 1 · IOM 1046-02
O Ring - Seal SleeveCat 47 · Qty 1 · IOM 1046-02
O Ring - Seal SeatCat 48 · Qty 1 · IOM 1046-02
BodyCat 1 · Qty 1 · IOM 1046-02
CoverCat 2 · Qty 1 · IOM 1046-02
ShaftCat 21 · Qty 1 · IOM 1046-02

How we confirm the exact part: Ebsray parts are ordered by name, Cat # and quantity against the pump serial number on the nameplate, as each IOM instructs, because materials, seals and options vary by build. Cat numbers on this page are as printed in the current Ebsray installation, operation and maintenance instructions (IOMs). Send the serial number or a nameplate photo and we’ll confirm the right genuine parts before we quote.

Service Intervals & When to Replace

  • Periodic inspection (RB10): Maximum interval of three months or 500 hours – check for LPG leaks, vibration, noise, overheating, coupling wear, differential pressure and motor current, and record it in the Pump Run Log. No in-service lubrication is required.
  • Carbon sleeve bearings (RB10): Running clearance should not exceed 0.15 mm for the cover bearing and 0.25 mm for the first stage impeller housing bearing. Check shaft run-out if the journals are worn.
  • Impellers: The RB10 second stage impeller and the R10 impeller have a minimum width of 8.86 mm and minimum diameter of 129.86 mm. Replace if the blades are broken or wear is excessive.
  • Bearings and seal: RB10 ball bearing replacement is recommended at 10,000 operational hours, and both models should have new ball bearings at major overhauls. Check the mechanical seal faces and replace as required.
  • O-rings and gaskets: Replace O-rings at every overhaul (and flange gaskets on the RB10). Never let carbon seal faces get marked or chipped during handling.

Models

This page covers Ebsray RB10 and R10 pumps. The model, type and serial number are on the pump nameplate; Ebsray matches spares to the serial number.

RB10R10

Models & Key Specifications

ModelTypeMax flowMax differentialParts list
RB10Regenerative turbine140 L/min (50 Hz)11 barIOM 1069-10
R10Regenerative turbine (legacy)––IOM 1046-02

RB10 figures from Ebsray’s RB10 product data. The R10 is a legacy model; parts are listed from its IOM and confirmed on serial number. LPG pump parts must be fitted by a licensed gas fitter or a qualified technician.

Troubleshooting

Pump running but not building differential pressure

Likely cause: The pump has not primed because of low tank level, a closed inlet valve, sun heating the pump and inlet piping, or vapour unable to clear through a restricted bypass return line. Action: Fill the tank, open the inlet valve, shade the pump or paint it and the piping white, and keep the return to tank unrestricted (no back-check valve in that line).

Discharge pressure too low or slow fill

Likely cause: The bypass is set too low or jammed open, there is inlet restriction, vapour pressure is low (high butane or a cold tank), or the pump has normal wear. Action: Increase the bypass setting without exceeding motor FLA, free the bypass valve, open or repair the inlet valves, and service or replace the pump if worn.

Motor overheating or using excessive power

Likely cause: The bypass is set too high, the discharge is restricted or closed, the power supply is faulty, debris is jamming the pump, or the impellers are damaged. Action: Lower the bypass setting, open the discharge, check the supply, remove debris from the pump, tank and inlet pipe, and replace damaged impellers.

Leakage from casing or seal

Likely cause: Damaged casing O-rings, or a worn, cracked or incorrectly set mechanical seal – shown by liquid at the telltale hole at six o’clock under the body. Action: Check the O-rings and the axial movement of the rotating face, reset the 0.5 mm gap between seal sleeve and rotary face, or replace the seal.

Request for Quotation

Selected Parts:

  • No parts selected

Not sure which parts? Just send a photo of the nameplate or part below.

Your pump

Please select your Ebsray model (or choose “Not sure”)

Your details

Please enter your full name
Please enter a valid email address
Please enter a valid phone number

Your enquiry

Please select what you need

Drag & drop image here or tap to browse

JPG, PNG or PDF, max 5MB

File must be smaller than 5MB

Delivery

Please select when you need it
Please enter the delivery suburb or town
Please enter a 4-digit postcode
Postcode and state don't match - please check
Please select a state
Please select a delivery type

We use these details only to prepare and follow up your quote. See our Privacy Policy.

We aim to respond within one business day

Ebsray RB10 and R10 spare parts: frequently asked questions

Tap a question to see the answer.

What spare parts are listed for Ebsray RB10 and R10 pumps?

Each section follows the parts designation list in the Ebsray IOM for that model or pump type (RB10 and R10), with the Cat # as printed. Seals come first, then the main wearing parts, bearings, O-rings and gaskets, valve parts and the main castings.

How do I order the right parts for my Ebsray pump?

Ebsray matches spares to the serial number on the pump nameplate, together with the part name, Cat # and quantity. Tick the parts you need, pick your model in the quote form and add a nameplate photo, and we will confirm the exact genuine parts before quoting.

Pump running but not building differential pressure: what should I check?

Fill the tank, open the inlet valve, shade the pump or paint it and the piping white, and keep the return to tank unrestricted (no back-check valve in that line). The troubleshooting table on this page lists the other likely causes.

Do you supply parts for other Ebsray pumps?

Yes. We list parts for Ebsray LPG regenerative turbine, rotary vane and internal gear pumps. See our Ebsray LPG turbine pumps or all Ebsray spare parts by series. Not sure which series you have? Send a nameplate photo and we’ll identify it.